Tuesday, March 7, 2023

Curlin pump manual.MOOG CURLIN INFUSION PAINSMART USER MANUAL Pdf Download | ManualsLib

Looking for:

Curlin pump manual 













































    ❿  

Curlin pump manual.Inquiry about Curlin 6000 CMS



 

Here are the pumping mechanism, dimensions, weight and etc. Download curlin medical cms and curlin medical cms manual. The maximum volume that may be infused under Single Fault Conditions is 0. Recommended administration set usage not to exceed 72 hours. Curlin CMS The Moog Curlin CMS Infusion pump is an easy-to-use, ambulatory or pole mounted infusion device designed to meet the needs of the hospital or alternate site patient.

Features Shift Totals that can be greater than 24 hours. User-friendly, easy-to-teach programming that shortens staff in service time and patient teaching time.

Three tamper-resistant lock settings to assist in maintaining patient compliance and safety. Attractive yet robust design that is impact resistant and water resistant. Audio alarms that can be adjusted from 1 very quiet to 9 loudest to meet specific patient and clinical setting needs but that cannot be totally disabled. Page 15 Moog representative. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation.

With a little introduction and training, an operator will quickly be able to program and use these pumps to deliver the therapies prescribed. Page Figure 2. When the set is new, the Integral Flow-Stop has a breakaway tab that keeps the Integral Flow-Stop open and allows the tubing to be gravity primed. Review the following illustrations: Figure 2.

Use aseptic technique and universal precautions as directed by the policies of your healthcare facility or institution. Dispose of administration sets in accordance with all applicable regulatory and institutional Fully open the door of the pump. This feature notifies you if an occlusion is present between the IV container and the pump.

C-cell batteries are readily available at most retail facilities that carry alkaline batteries. Use a small coin such as a penny to depress the pin. Page 35 5 and 40 degrees celsius. If the fault condition persists, then the battery pack should be returned to Moog Medical Devices Group for replacement of the battery. The AC Adaptor can also be used to recharge the portable battery pack by plugging the connecting cable into the recharging port on the battery pack.

When a bolus dose is requested two beeps will sound to indicate that the dose has started. If a bolus dose is requested and denied, one beep will sound. It may be helpful to read through these steps first, and then go back and use them to operate the Moog Curlin Infusion pump. Page Keypad Function 5. Note: The Moog Curlin Infusion pump requires you to actively change a selection.

The Up arrow or Down arrow will not change a selection. Changes to this screen are not allowed. Date Time 2. Page 44 5. Within the allocated 15 seconds, the user can scroll up or down the screen. Page 45 8. Page Display Screen Display Screen The display screen provides a maximum of four lines of text, or fields, at any one time for feedback regarding the pump status and data entry. It notifies the user with prompts or messages when necessary. Page Basics Of Programming Chapter Basics of Programming The Moog Curlin Infusion pump allows the operator to customize this device to meet the specific infusion needs of each individual patient.

This chapter will explain the customizing features along with the programming steps. Data Entry Screens are used to specify prescription parameters.

Sample of a Data Entry Screen In the above example, the cursor rests on a field requiring numeric data entry for specific prescription information, e. The operator enters the correct information using the numeric keys and decimal point key.

Page Using "Help Some error notices may reset the pump back to its default settings and therefore will require reprogramming. Page Power Status Screen Power Status Screen This screen displays the active power source of the pump, whether internal batteries or external power. If the active source is the C-cell batteries, a bar graph will indicate the amount of power remaining in the batteries.

This graph is only an approximation of the charge left and is not intended to give a specific representation of battery life. Page 55 Welcome Screen. If the maintenance due date will occur during the time the patient will be on service, the clinician may wish to select another Moog Curlin Infusion pump for this patient. When the history log is full, it will overwrite on a first-in, first-out basis.

The pump will display Page Changing Date And Time Changing Date and Time A notification screen displays, and a prompt is given to run the pump. At this time, you can continue to infuse the prescription from the exact point at which it was interrupted. Page Resuming A Library Therapy 9. Note: Some options may be hard locked so that changes cannot be made or there may be preset limits that cannot be exceeded for safety. It is designed for therapies requiring a continuous rate of infusion, patient controlled boluses, or both.

Page Administration Routes 3. Each of the routes has defined settings as illustrated in the following table: A d m i n i s t r a t i o n R o u t e s Page Pca Prescription Menu The range for this field is 1 to Use the numeric keys to enter the prescribed rate the units chosen in the Pre-Prescription Menu will appear here. Page Prime Direction Screen 1. Page Options Note: The amount of fluid used in the priming process will be deducted from the Bag Volume Total but will NOT be counted in the amount infused because this amount is not to be delivered to the patient.

The bag volume should still be equal to or greater than the Amount TBI before you can proceed with the infusion. Page Clinician Dose Menu require a clinician access code. Clinician Dose : Allows an additional prescribed dose to be administered by a clinician at any time except during a Load Dose or Bolus Dose. It toggles with the amount of time elapsed since that clearing. Page Clear Hourly Totals Screen 5. The alert message below will then briefly appear on the screen.

If the alert occurred at the Run Options screen, the pump will start the infusion. The pump will begin infusing, and except when a Load Dose or Clin Dose is programmed, the following screen will display data on the status of the therapy: P C A R u n Page Pca Information Screens P C A I n f o r m a t i o n S c r e e n s Note: The top line of these running screens will display the name of the running protocol when programmed in the Library mode, or it will display "Unidentified" when programmed outside of the library.

If more than one therapy is programmed, a Select Therapy Screen will list all preprogrammed therapies. The display will return to the Pre-Prescription Screen. If the current container has not completely infused, the following screen will appear: a. Page Stopping The Infusion 2.

A completely filled in bar graph indicating infusion complete. Page 85 b. The lock setting can control access to this function. Page Troubleshooting Troubleshooting This section assists in identifying and resolving alert and alarm conditions that may occur during the use of the Moog Curlin Infusion pump.

Alerts, Alarms, and Error Codes Alerts, Alarms, and Error Codes are classes of events that are relayed to the user and logged into the history file.

Page 87 remainder of the infusion. Page 88 Cause: Occurs when bag volume is less than amount to be infused. Advise patient of time limits between bolus doses per agency protocols.

This feature will erase all programmed therapies in the pump. The date and time can then be changed. Page 91 Alert: Cancellation of a clinician dose is pending and can only be processed with the pump running. Cause: Clinician dose in progress is canceled while the infusion is paused; and the user attempts to enter a new Clinician Dose, prior to resuming the infusion Resolution: Resume the infusion and then program the desired Clinician Dose.

❿     ❿